Crown Boiler Co. AWR140BNST3P8U
Crown Boiler Co. AWR140BNST3P8U
Hover to zoom
1 Of 5

Crown Boiler Aruba 5 - 117K BTU - 84% AFUE - Hot Water Gas Boiler - Chimney Vent - 2,000 to 8,000 Ft. Altitude

Model:

AWR140BNST3P8U

Write A Review
$2,627.00
Free Shipping
&
Lift Gate
  Learn More About Free Freight
Free Shipping & Lift Gate
*This product qualifies for Free Shipping anywhere in the contiguous US. Accessories may ship separately. Items over 100lbs shipped via semi-truck, be sure to select "Lift Gate" to lower the product to the ground curbside. Remote area surcharges may apply, see our full shipping policy for more details.
Factory-Direct
Ships in 6-8 Weeks
synchrony card logo
$46 / Month
With our 86 months 11.99% APR*
86 fixed monthly payments required.
Crown Boiler Aruba 5 - 117K BTU - 84% AFUE - Hot Water Gas Boiler - Chimney Vent - 2,000 to 8,000 Ft. Altitude
Crown Boiler Aruba 5 - 117K BTU - 84% AFUE - Hot Water Gas Boiler - Chimney Vent - 2,000 to 8,000 Ft. Altitude
Model: AWR140BNST3P8U
$2,627.00
Accessories
Features
Specifications
Reviews
Product Q&A
How-To Articles
Manuals
Share

Recommended Accessories

Power Equipment Direct expert image
Expert Recommended Accessories Selected by Ken, our Expert
Required Accessories 9
These accessories are required to properly setup/install this product.
Optional Accessories 10

Features

    The Aruba line of boilers has been a long standing signature line for Crown with its rock solid reliability and adaptability to nearly any installation conditions. At its core is a sturdy cast iron heat exchanger guaranteed to withstand years of operation without a hitch. A proprietary boiler control is included with the boiler, providing a single access point for low water cutoff, temperature, and ignition configuration. Gas can be supplied to the boiler from either side, allowing the Aruba to fit into nearly any space in your utility room. Proven in thousands of installations, the Aruba is a solid choice for any home heating application.
  • Cast Iron Heat Exchanger
  • The heat exchanger at the core of the Aruba 5 is made of durable cast iron, a material proven many times over for its reliability in heating applications.
  • Included Proprietary Control
  • This boiler comes with a control designed in-house specifically for operation with the Aruba 5 line. Because the control is designed to fit the boiler, it improves the reliability of operations and integrates seamlessly into unique applications.
  • Built-In Rear Draft Diverter
  • Crown's Aruba 5 boilers come stock with a rear draft diverter, making the boiler perfectly suited to low clearance installations.
  • Easily Convertible to Left Side Piping
  • The internal layout of the boiler makes field conversion to left side supply and return piping a simple task, further increasing the versatility of the Aruba 5's placement in your utility room.
  • Low Water Cut-Off
  • A low water cut-off comes standard in each Aruba 5 boiler, preventing damage or boiler explosion by turning off electric power when water loss is detected.
  • Included Circulator
  • Each Aruba 5 boiler includes a Taco circulator pump for efficient home heating.
California residents see
Warning: This product can expose you to chemicals including Chromium (hexavalent compounds) which is known to the State of California to cause Cancer.
For more information go to: www.p65Warnings.ca.gov

Specifications

AWR140BNST3P8U
specs product image PID-103109
Overview
Product Category
Boiler
UPC
645504509578
General Information
Product Line
Aruba 5
Product Category
Boiler
Medium Learn More
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type Learn More
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production Learn More
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Staging
Mount Type
Floor
Minimum Altitude
2000 Feet
Maximum Altitude
8000 Feet
Includes Pump
Yes
Assembly Type
Packaged
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
84 %
Maximum Input Capacity Learn More
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
140000 BTU
DOE Heating Capacity Learn More
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
117000 BTU
Net I=B=R Capacity Learn More
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
102000 BTU
Ultra Low NOx Emissions Learn More
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
6 Inches
Supply Connection
1 1/4 Inches
Return Connection
1 1/4 Inches
Product Height
39 1/2 Inches
Product Width
18 1/2 Inches
Product Depth
31 1/2 Inches
Shipping Weight
384 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
202247241
Warranty Information
Warranty Learn More
Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
20 Years

Reviews

(1)
Crown Boiler Co. AWR140BNST3P8U Reviews & Ratings

Product Q&A

Expert avatar photo
Be the First to Ask A Question Answered by Ken, the eComfort Product Expert

How-To Articles

How to Pick the Perfect Boiler
How to Pick the Perfect Boiler
At the heart of every boiler heating system is the boiler itself. It's responsi...
A Break-Down of Boiler Fuel Options
A Break-Down of Boiler Fuel Options
In many homes around the world, a boiler is essential. A boiler can provide hea...
Home Boiler System Overview
Home Boiler System Overview
If you just bought a house in the northeast, chances are it gets heat from a re...
Power Equipment How-To Library
Power Equipment How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Crown Boiler Aruba 5 - 117K BTU - 84% AFUE - Hot Water Gas Boiler - Chimney Vent - 2,000 to 8,000 Ft. Altitude
Crown Boiler Co. AWR140BNST3P8U
Customer Review Images