Features
- Advanced Heat Exchanger Design
- The GMVC96 furnace employs a reliable dual-diameter tubular heat exchanger design. Aluminized steel is used for incredibly efficient heat transfer, and a wrinkle-bend is applied to the tubes to enhance the heat exchanger's dependability and longevity.
- Secondary Heat Exchanger
- This furnace produces additional heat by directing combustion gases through a secondary heat exchanger before they are vented. The secondary heat exchanger is made of corrosion-resistant stainless steel and it is sloped to prevent condensate build-up.
- Quiet Comfort
- The blower and gas valve of the GMVC960403BN were selected for their incredibly low sound levels. Additionally, this unit offers an airflow system and fan speed options that allow it to operate quietly while providing consistent comfort.
- Venting Options
- The GMVC960403BN offers several venting options to streamline installation in a variety of applications. It can be used in either a two-pipe direct vent setup or a single-pipe configuration with combustion air.
- Secure Cabinet
- All GMVC96 furnaces are protected by a durable steel cabinet rated for less than 2% air leakage. The heat exchanger section is insulated to prevent heat loss and the return side of the cabinet is solid and airtight.
- ComfortBridge Compatible
- This furnace is compatible with Goodman's ComfortBridge communicating controls. ComfortBridge control streamlines the installation and maintenance processes further by automatically detecting your equipment and providing diagnostics and troubleshooting.
- Auto-Comfort
- Goodman's Auto-Comfort mode is available in applications where the GMVC960403BN is used to distribute cooled air. This mode scales output up to the cooling demand in stages for improved comfort, efficiency, and dehumidification.
- Easy Integration
- The GMVC960403BN makes it simple to enhance your system with a humidifier and an electronic air cleaner; just wire them directly to the low-voltage terminals on the control board.
- Extended Warranty
- Goodman offers a 10-year limited unit replacement and parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See the "Manuals" tab for more information.
Overview for Goodman GMVC960403BN Gas Furnace HeaterThe Goodman GMVC96 High-Efficiency Gas Furnace with two-stage gas valve and a variable-speed circulating blower provides efficient and economical performance. Unlike single-stage gas furnaces that operate 'all on' or 'all off,' a Goodman two-stage gas furnace typically runs at the lowest possible speed to precisely maintain a constant, steady temperature in your home. A two-stage gas furnace optimizes its heating output to maximize indoor comfort and lower energy costs. When operating at low-speed levels, your Goodman gas furnace consumes less energy to keep your home comfortable. In addition, the 96% AFUE rating on this gas furnace means that 96 cents of every $1.00 of heating energy expense warms your home.
The Goodman GMVC96 96% AFUE Two Stage, Variable Speed, Multi position Upflow ComfortNet Compatible Series GMVC960403BN Gas Furnace Heaters.
The Goodman brand is one of the biggest names in home cooling, heating and energy-efficient home comfort.
California residents see
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
For more information go to: www.p65Warnings.ca.gov
Specifications
GMVC960403BN
Overview
Product Category
Furnace
UPC
663051560956
Additional Model Numbers
GMVC960403BN, GMVC960403BN
General Information
Type
Gas Furnace
Product Line
GMVC96
Product Category
Furnace
Fuel Type
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Motor Type
ECM Variable-Speed
Configuration
Configuration
Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
DOE Regional Compliance
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide (Except CA)
Installation Available
Yes
Performance
AFUE
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
96 %
Heating BTU
40000
High Fire Input
40000 BTU
High Fire Output
38400 BTU
Low Fire Input
28000 BTU
Low Fire Output
26880 BTU
Maximum Air Flow
1200 CFM
Ultra Low NOx Emissions
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Low NOx Emissions
Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
7.8 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
2 or 3 Inches
Cabinet Width
17 1/2 Inches
Product Height
34 1/2 Inches
Product Width
17 1/2 Inches
Product Depth
28 3/4 Inches
Product Weight
114 Pounds
Shipping Weight
114 Pounds
Certifications
Energy Star Listed
Yes
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
7368841
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
20 Years
Reviews
(11)
Goodman GMVC960403BN Reviews & Ratings
How-To Articles
How Gas Furnaces Work
Do you wish you had a better grasp on things when the heat goes out and your fa...
How Does a Gas Furnace Work
We're all familiar with the comforting sound of a home furnace warming up; that...
How to Pick the Perfect Furnace
The heart of nearly every forced air heating system is the furnace. Gas furnace...
Manuals
Ask A Question!
*Required Fields
+
Thank You For Submitting Your Question
Your submission has been sent successfully. Please give our experts up to two business days to respond.
Media Gallery
Goodman 96% AFUE 40,000 BTU Variable Speed Upflow Gas Furnace
Customer Review Images