Burnham 305BNI-T
Burnham 305BNI-T
Hover to zoom
1 Of 5

Burnham 305 - 117K BTU - 84.0% AFUE - Hot Water Gas Boiler - Chimney Vent

Model:

305BNI-T

Write A Review
$3,668.01
Free Shipping
&
Lift Gate
  Learn More About Free Freight
Free Shipping & Lift Gate
*This product qualifies for Free Shipping anywhere in the contiguous US. Accessories may ship separately. Items over 100lbs shipped via semi-truck, be sure to select "Lift Gate" to lower the product to the ground curbside. Remote area surcharges may apply, see our full shipping policy for more details.
Factory-Direct
Ships in 7-14 Business Days
synchrony card logo
$65 / Month
With our 86 months 11.99% APR*
86 fixed monthly payments required.
Burnham 305 - 117K BTU - 84.0% AFUE - Hot Water Gas Boiler - Chimney Vent
Burnham 305 - 117K BTU - 84.0% AFUE - Hot Water Gas Boiler - Chimney Vent
Model: 305BNI-T
$3,668.01
Accessories
Features
Specifications
Reviews
Product Q&A
How-To Articles
Manuals
Share

Recommended Accessories

Power Equipment Direct expert image
Expert Recommended Accessories Selected by Ken, our Expert
Required Accessories 9
These accessories are required to properly setup/install this product.
Optional Accessories 10

Features

    Burnham is devoted to pushing the limits of heating technology and efficiency. Their ingenuity is responsible for some of the most efficient boilers on the market today. The Series 3 line of hot water boilers blends a reliable design with Burnham's cutting edge IQ Control System. Series 3 boilers save energy by doubling down on heat retention with an insulated jacket and plates. Possessing industry standard tapping locations, simplified venting, and exceptional efficiency, the 305BNI-T is an excellent replacement for older natural draft boilers or the perfect addition for new construction.
  • Intelligent Hydronic Control
  • Burnham's IQ system consists of two primary components: an IQ Option Panel and an Intelligent Hydronic Control. The IHC supports two setpoints, controls ignition, provides fan and circulator relays, and acts as an aquastat.
  • IQ Option Panel
  • The IQ Option Panel provides a standardized and simplified way to add functionality to your boiler. It supports Burnham's plug-and-play IQ Option Cards for outdoor reset, an auxiliary high limit, and low water cutoff.
  • Compact Venting Technology
  • All Series 3 boilers contain a draft diverter. By internalizing this component, the profile of the boiler and the space required for installation is reduced. The 305BNI-T also includes a vent damper to provide ideal combustion conditions.
  • Durable Construction
  • Cast-iron construction of the boiler sections contribute to the incredible longevity of Series 3 models. The heat exchanger is also made of cast iron, which allows it to accept lower return water temperatures.
  • Product Includes
  • (1) Burnham 305BNI-T Hot Water Boiler
  • (1) Burnham 102284-03 6" Vent Damper
  • (1) Taco 007-2 Circulator
  • (1) Miscellaneous Parts Bag
  • (1) Instruction Envelope
  • Product Note
    A high altitude conversion kit is required for installations made at altitudes above 5,400'.
California residents see
Warning: This product can expose you to chemicals including Chromium (hexavalent compounds) which is known to the State of California to cause Developmental Harm.
For more information go to: www.p65Warnings.ca.gov

Specifications

305BNI-T
specs product image PID-38005
Overview
Product Category
Boiler
General Information
Product Line
Series 3
Product Category
Boiler
Medium Learn More
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type Learn More
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production Learn More
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Staging
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
10000 Feet
Assembly Type
Packaged
Includes Pump
Yes
Gas Conversion Kit
Available
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
84 %
Maximum Input Capacity Learn More
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
140000 BTU
DOE Heating Capacity Learn More
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
117000 BTU
Net I=B=R Capacity Learn More
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
102000 BTU
Ultra Low NOx Emissions Learn More
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
6 Inches
Gas Connection Size
1/2 Inch
Supply Connection
1 1/4 Inches
Return Connection
1 1/4 Inches
Product Height
41 Inches
Product Width
18 1/2 Inches
Product Depth
33 Inches
Product Weight
284 Pounds
Shipping Weight
357 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
ASME Certified
Yes
AHRI Certified
Yes
AHRI Reference Number
2101373
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
Limited Lifetime Years

Reviews

(2)
Burnham 305BNI-T Reviews & Ratings

Product Q&A

Expert avatar photo
Be the First to Ask A Question Answered by Ken, the eComfort Product Expert

How-To Articles

How to Pick the Perfect Boiler
How to Pick the Perfect Boiler
At the heart of every boiler heating system is the boiler itself. It's responsi...
A Break-Down of Boiler Fuel Options
A Break-Down of Boiler Fuel Options
In many homes around the world, a boiler is essential. A boiler can provide hea...
Home Boiler System Overview
Home Boiler System Overview
If you just bought a house in the northeast, chances are it gets heat from a re...
Power Equipment How-To Library
Power Equipment How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Burnham 305 - 117K BTU - 84.0% AFUE - Hot Water Gas Boiler - Chimney Vent
Burnham 305BNI-T
Customer Review Images